TrackCube Ex

Possible uses

  • ic_05
  • ic_06
  • ic_07
  • ic_08
  • ic_09
  • ic_04
  • ic_01
  • ic_04

TrackCube Ex is certified for use in Zone 1, pursuant to the ATEX guideline. TC Ex is developed specifically for data collection and location of:

  • tank containers
  • tank wagons
  • industrial vehicles

System function / alarm function:

  • Sensor alarms on movement during a lockout period
  • Area alarm when leaving or entering an area
  • Push detection
  • traveled distance recording
  • operating hours counter
  • Temperature monitoring
slider imageslider imageslider imageslider image
TC-Ex-(1)
TC-Ex-(2)
TrackCube Ex
TC-Ex-(5)

Temperature sensor TSK3

  • Temperature monitoring: alarm messaging when threshold values are not met
  • Mounting of the temperature sensor: the sensor can be glued e.g. to the surface of a tank container, the length of the connection cable can be adjusted to the local situation

Power supply

  • the power supply is provided by a lithium battery pack
  • the battery pack is suitable for use in the explosion-protected system
  • The power supply is designed for long-term operation for several years: The energy consumption depends on the connected sensors, the desired system and reporting behavior, and the environmental conditions for GPS satellite reception and the GSM – broadcast supply.

Note:

Only certified battery packs may be used as power supply for TrackCube Ex. Otherwise, the certification conditions are not met.

System certificastion

ATEX

  • EC type examination certificate No. FTZÚ 13 ATEX 0146
  • Gases und vapor: II 2G Ex e ib [ib] mb IIB T4 Gb
  • Dust: III 2D Ex [ib] tb IIIB T125 °C Db

Temperature sensor TSK3:

  • EC type examination certificate No. FTZÚ 13 ATEX 0147
  • Gases and vapor: II 2G Ex ib IIC T4 Gb
  • Dust: III 2D Ex ib IIIC T 130°C Db

Rail use

In addition, TrackCube Ex is designed for use in rail and fulfills the relevant standards for use with rail vehicles.

DIN EN 50 121-3-2 Rail use - electromagnetic compatibility (EMC)

DIN EN 50 155 Rail use - electromagnetic installations on rail vehicles

Technical data temperature sensor TSK3

  • EC type examination cerificate No. FTZU 13 ATEX 0147
    According to: EN 60079-0:2012, EN 60079-11:2012
  • ATEX:
    II 2F Ex ib IIC T4 Gb (gases and vapor)
    II 2F Ex ib IIC T 130° Db (dust)
  • Sensor unit with copper plate: 40 x 50 [mm]
  • High-grade HELUTHERM connection cable: 2 x 0.5 mm2, halogen-free, weather-proof and oilresistant
  • Cable lenght: max. 10m
  • Temperature range: -55°C to+125°C
  • Accuracy: +/- 0.5°K in range
    from -10°C to +85°C
  • Safety class : IP67

Technical data TC Ex

  • EC type examination certificate No. FTZU 13 ATEX 0146
    According to: EN 60079-0:2012, EN 60079-7:2007, EN 60079-11:2012, EN 60079-18:2009
  • ATEX:
    II 2G Ex e ib [ib] mb IIB T4 Gb (gases and vapor)
    II 2D Ex [ib] tb IIIB T 125° Db (dust)
  • GSM / GPRS Quad Band Modem
  • Integrated GSM and GPS antenna
  • GPS receiver, 50 channel Supersense
  • Motion/ vibration detector
  • 3 axis accelerometer
  • 2 analog inputs, intrinsically safe "ib"; 2 digital inputs, enhanced safety "e"; 2 analog inputs 4 to 20mA, enhanced safety "e"; 1 switchable outpit via potential-free relay contact, enhanced safety "e"
  • Power supply: Lithium battery pack (component of certificate)
  • Housing: stainless steel, L/B/H 208 x 171 x 90 [mm]; 4 cable inlets, metal, ATEX-conform
  • Safety class: IP67
  • Temperature range: -25°C to +60°C
  • Weight: 3.7kg